C-ARM MACHINE

C ARM - H RAY 20

The “C-arm HRAY-20” machine is a specific model or variant of the C-arm imaging system used in the medical field. It likely features advanced imaging capabilities and mobility that are typical of C-arms. This type of machine is commonly used in a variety of medical specialties, such as orthopedics, cardiology, vascular surgery, and more. The “HRAY-20” designation may indicate certain technical specifications or features unique to this model, but without specific information, it’s challenging to provide precise details. Nevertheless, C-arm machines like the HRAY-20 play a vital role in modern medicine, providing real-time X-ray imaging during surgical and interventional procedures, improving the accuracy and safety of these medical interventions.

Technical Specifications

Camera Specification (1K X 1K)

  • Resolution                             1280*1024
  • Frame Rate                             30FPS
  • Mega Pixel                              1.3MP
  • Type of sensor                         CMOS
  • Read out Method                      Global shutter.
  • Sensor Format                          1/1.8”
  • Pixel Size                                5.3m
  • Lens Mount                              CS-mount.
  • ADC                                        10 bit
  • Quantum efficiency                   60
  • Gain Range                               0 dB to 18dB
  • Exposure Range                         0.016ms to1 sec.
  • Trigger Modes                           Standard, multi-shot
  • Partial Image Modes                   Pixel binning, decimation, ROI.
  • Image Buffer                             16 MB
  • User Sets                                  2 user configuration sets for custom camera setting
  • Flash Memory                            512 KB non-volatile memory
  • Opt-isolated I/O Ports                 1 Input, 1 Output
  • Auxiliary Output                        3.3V, 150mA maximum
  • Interface                                  GigE PoE
  • Power Requirements                    12v nominal (5-16V) via GPIO interface.
  • Power Consumption (Max)             2W

X-Ray Generator

  • Type                                               High Frequency:70kHz
  • KV Range(fluoroscopy/radiography)      40 to 110kVp
  • Fluoroscopy                                      4 mA
  • Boost Mode                                       5 mA
  • Radiology mAs                                  100 mAs
  • Output                                            2.5 kW

Imaging System

  • X-Ray Image Intensifier           9” (Toshiba)
  • Grid                                     Round 9”-Ratiom- 8:1,Line103
  • Vertical Run                          400 mm
  • Horizontal Run                       200 mm
  • Angulations                          ±1800
  • S.I.D                                     960 mm
  • Arc Distance                          600 mm
  • Clearance                              750 mm

Imaging System

  • Tube Head                                     Monoblock
  • Type of X-Ray Tube                         Stationary Anode
  • Focal Spot                                     Dual(Small-06mm/large- 1.8mm)
  • Make                                            Germany